  • Model NO.: YJV YJV22 YJV32 YJV42 YJV62 YJV72
  • Voltage: High Voltage Cable
  • Insulation Material: XLPE
  • Material Shape: Round Wire
  • Certification: ISO, IEC
  • Brand: Qiangling
  • Insulation: XLPE
  • Cross Section: 240-2500mm2
  • Fire Resistance: Available, as Per Customer′s Requirement
  • Waterproof: Available, as Per Customer′s Requirement
  • Applied Standard: IEC 60840
  • Origin: Yangzhou, Jiangsu, China
  • Application: Construction, Underground, Industrial, Power Station, Telecommunication
  • Current: AC Cable
  • Sheath Material: PVC
  • Wire Core Material: Red Copper Wire
  • Model: YJV
  • Voltage Range: 35-220kv
  • Conductor: Copper or Aluminum
  • Core Number: 1
  • Flame Retardant: Available, as Per Customer′s Requirement
  • Cold Proof: Available, as Per Customer′s Requirement
  • Trademark: Qiangling
  • HS Code: 8544492100
Product Description

Product Description

HV & EHV/optical fiber/XLPE insulation/corrugated Al/PVC sheath/electric power cable

Product Range
Rated voltage 66~500kV XLPE insulated power cables

Product comply with the standard/specifications as following
GB/T 11017  Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 110kV
GB/Z 18890  Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV(Um=252kV)
GB/T 22078  Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV(Um=550kV)
IEC  60840  Power cables with extruded insulation and their accessories for rated voltage above 30kV(Um=36kV) up to 150kV(Um=170kV)
IEC  62067  Power cables with extruded insulation and their accessories for rated voltages above 150kV(Um=170kV) up to 500kV(Um=550kV)
And customer technical specification


Structure Description

ConductorAdopting copper or aluminum, it depends on economic consideration.
Tightly compressed conductor with good roundness and smooth surface.
Those above 800mm2 adopt five sectors design to reduce skin effect and neighboring effect.
Semi-conductive wrapping tape is to prevent penetration from inner screen to conductor and improve smoothness of inner screen.
Inner/Outer screenAll adopt imported super-smooth cross-linked polyethylene screen material. The surface shall be smooth and electric field shall uniformly distribute.
InsulationAdopt imported super-smooth cross-linked polyethylene insulation material.
Extruded with inner and outer screens together, compactly combined.
Using gravity feeding to prevent external influences and ensure purity of raw material.
Advanced process expels internal stress of insulation. High roundness and small eccentricity.
Water buffer layerHigh-performance water-blocking material ensures better water blocking property of cables.
Buffer layer design ensures enough expansion space for insulation.
Metallic screenMeets the requirement of metallic screen and system short-circuit capacity.
Radial waterproof corrugated aluminum sleeve has excellent mechanical strength to protect insulated cores of cable.
Or, adopt copper wire screen.
BitumenAnti-corrosion asphalt can effectively protect aluminum sleeve.
Over sheathExtruded PE or PVC material
Optional low smoke low halogen and low smoke zero halogen material
Optional flame retardant, termite prevention materials, to meet the need in different occasions.
Semi-conductive layerContinuous, bright graphite coating, as the electrode of outer sheath for voltage test.
Optional extruded semi-conductive layer.

Quality Assurance
Provide customers with fine products and service, fully follow ISO9001 qualify management system, from cable design, manufacturing, inspection, delivery to after sales service.


The 700kV 35A 24500kVA series resonance test system and type DDX-7000 partial discharge measuring instrument from Haefely in Switzerland can meet the requirement of cable factory routine test, sample test and some type test.

Technical Data
Single Core, XLPE Insulation, Corrugated Aluminium Sheath, PE/PVC over sheath Power Cables
Copper Conductor, CSA Sheath    Type: YJLW03(2)-Z

Rated Voltage     50/66 kV
Conductornominalsectionmm2240300400500630800(C)800(M)100012001400160020002500
- shape Compacted circular conductor Milliken conductor
nominal diametermm18.420.623.826.630.033.835.139.342.245.748.754.560.9
Insulationnominalthicknessmm14.014.014.014.014.014.014.014.014.014.014.014.014.0
-   nominal diametermm49.051.254.457.260.664.467.171.974.878.381.387.193.5
CSA- nominalthicknessmm2.02.02.02.02.02.02.02.32.32.32.32.52.6
- nominal diametermm67.970.173.376.179.784.387.092.896.1100.0103.4110.4117.6
                             
Non-metallic sheath -nominal thickness
mm4.04.04.04.04.04.04.54.54.54.55.05.05.0
Cable                      - approx diametermm76.278.481.684.488.092.696.3102.1105.4109.3113.7120.7127.9
 approx weightkg/m6.67.38.49.611.113.013.616.217.920.022.326.631.4
Mechanical, Electrical Performance
Max pulling forcekN16.821.028.035.044.156.056.070.084.098.0112.0140.0175.0
Min bending radiusmm1140118012201270132013901440153015801640171018101920
                             
Conductor resistanceDC at 20ºC
Ω/km0.07540.06010.04700.03660.02830.02210.02210.01760.01510.01290.01130.00900.0072
 
   - AC at 90ºC
Ω/km0.09700.07770.06130.04840.03830.03090.02870.02310.02000.01740.01540.01270.0107
Inductance                  - trefoilmH/km0.4730.4560.4350.4200.4040.3900.3910.3800.3720.3630.3580.3480.337
flatmH/km0.7570.7340.7050.6830.6590.6350.6280.6050.5910.5750.5620.5400.517
Zero sequenceimpedance at 20ºCΩ/km0.150+ j0.0900.133+ j0.0860.117+j0.0800.104+ j0.0760.093+ j0.0700.084+ j0.0660.082+ j0.0670.068+ j0.0640.064+ j0.0610.060+ j0.0590.058+ j0.0570.053+ j0.0540.049+ j0.051
Core CapacitanceμF/km0.1510.1610.1770.1900.2060.2240.2370.2590.2720.2890.3030.3290.359
(50Hz)Charging currentA/km2.42.52.83.03.23.53.74.14.34.54.85.25.6
Short Circuit Rating
Conductor, at 1skA34.943.557.972.391.0115.4115.4144.1172.8201.4230.1287.4359.1
Conductor, at 3skA20.425.433.742.152.967.167.183.7100.3116.9133.5166.7208.1
Aluminium sheath, at1skA41.142.544.646.548.851.553.364.867.169.972.376.881.7
Aluminium sheath, at3skA24.825.626.928.029.431.132.238.940.341.943.445.948.8
Final Shart-circuitTemperatureºC250250250250250250250250250250250250250

Single Core, XLPE Insulation, Corrugated Aluminium Sheath ,PE/PVC over sheath Power Cables
Copper Conductor, CSA Sheath    Type: YJLW03(2)-Z


Rated Voltage     64/110 kV
Conductor- nominalsectionmm2240300400500630800(C)800(M)100012001400160020002500
shapeCompacted circular conductor  Milliken conductor
 nominal diametermm18.420.623.826.630.033.835.139.342.245.748.754.560.9
Insulation- nominalthicknessmm19.018.517.517.016.516.016.016.016.016.016.016.016.0
 nominal diametermm59.060.261.463.265.668.471.175.978.882.385.391.197.5
 CSA            nominalthicknessmm2.02.02.02.02.02.02.32.32.32.32.32.52.6
nominal diametermm80.381.582.584.787.590.793.499.2102.7106.6110.2117.4124.0
Non-metallic sheath -nominal thicknessmm4.04.04.04.04.54.54.54.55.05.05.05.05.0
Cable                     - approx diametermm88.689.890.893.096.8100.0102.7108.5113.0116.9120.5127.7134.3
 approx weightkg/m8.59.09.810.812.314.014.316.718.620.522.426.530.9
Mechanical, Electrical Performance
Max pulling forcekN16.821.028.035.044.156.056.070.084.098.0112.0140.0175.0
Min bending radiusmm1330135013601400145015001540163017001750181019202010
Conductor resistance  DC at 20ºCΩ/km0.07540.06010.04700.03660.02830.02210.02210.01760.01510.01290.01130.00900.0072
AC at 90ºCΩ/km0.09700.07770.06130.04840.03830.03090.02870.02310.02000.01740.01540.01270.0107
Inductance                    trefoilmH/km0.5030.4830.4580.4390.4230.4060.4030.3920.3860.3770.3700.3590.347
flatmH/km0.7570.7340.7070.6830.6590.6350.6280.6050.5910.5750.5620.5400.517
Zero sequenceimpedance at 20ºCΩ/km0.138+ j0.1010.122+ j0.0950.109+ j0.0870.097+ j0.0820.088+ j0.0760.080+ j0.0710.078+ j0.0720.065+ j0.0680.061+ j0.0660.058+ j0.0630.055+ j0.0610.051+ j0.0580.047+ j0.055
Core CapacitanceμF/km0.1240.1340.1510.1650.1830.2030.2140.2330.2450.2600.2720.2950.321
(50Hz)Charging currentA/km2.52.73.03.33.74.14.34.74.95.25.55.96.5
Short Circuit Rating
Conductor, at 1skA34.943.557.972.391.0115.4115.4144.1172.8201.4230.1287.4359.1
Conductor, at 3skA20.425.433.742.152.967.167.183.7100.3116.9133.5166.7208.1
Aluminium sheath, at 1skA48.949.750.551.853.455.557.269.271.674.476.981.486.1
Aluminium sheath, at 3skA29.530.030.531.232.233.534.541.543.044.746.148.751.5
Final short circuitTemperatureºC250250250250250250250250250250250250250

Single Core, XLPE Insulation, Corrugated Aluminium Sheath, PE/PVC over sheath Power Cables
Copper Conductor, CSA Sheath    Type: YJLW03(2)-Z

Rated Voltage   127/220 kV
Conductornominalsectionmm2400500630800(C)800(M)100012001400160020002500
shape Compacted circular conductorMilliken conductor
nominal diametermm23.826.630.033.835.139.342.245.748.754.560.9
Insulationnominalthicknessmm27.027.026.025.024.024.024.024.024.024.024.0
nominal diametermm81.484.285.687.489.791.994.898.3101.3107.1113.5
CSAnominalthicknessmm2.42.42.42.42.62.62.62.62.62.82.8
nominal diametermm108.5119.0113.5115.9118.4121.0124.3128.2131.2137.4143.8
Non-metallic sheath -nominal thicknessmm5.05.05.05.05.05.05.05.05.05.05.0
Cable                      -approx diametermm118.8129.3123.8126.2128.7131.3134.6138.5141.5147.7154.1
approx weightkg/m14.415.516.818.518.720.922.624.626.530.835.2
Mechanical, Electrical Performance
Max pulling forcekN28.035.044.156.056.070.084.098.0112.0140.0175.0
Min bending radiusmm17801940186018901930197020202080212022202310
Conductor resistanceDC at 20ºCΩ/km0.04700.03660.02830.02210.02210.01760.01510.01290.01130.00900.0072
AC at 90ºCΩ/km0.06130.04840.03830.03090.02870.02310.02000.01740.01540.01270.0107
Inductance                -trefoilmH/km0.5120.4880.4640.4400.4490.4300.4210.4100.4020.3880.374
flatmH/km0.7070.6830.6590.6350.6260.6050.5910.5750.5620.5400.517
Zero sequenceimpedance at 20ºCΩ/km0.094+ j0.1050.083+ j0.1000.074+ j0.0930.068+ j0.0870.067+ j0.0870.057+ j0.0810.054+ j0.0780.051+ j0.0750.049+ j0.0720.045+ j0.0680.042+ j0.065
Core CapacitanceμF/km0.1170.1250.1370.1510.1570.1730.1810.1910.1990.2150.232
(50Hz)Charging currentA/km4.75.05.56.16.36.97.27.67.98.69.3
Short Circuit Rating
Conductor, at 1skA57.972.391.0115.4115.4144.1172.8201.4230.1287.4359.1
Conductor, at 3skA33.742.152.967.167.183.7100.3116.9133.5166.7208.1
Aluminium sheath, at 1skA66.468.369.370.771.984.286.589.291.595.6100.4
Aluminium sheath, at 3skA39.840.941.542.443.150.351.753.354.757.059.9
Final short circuitTemperatureºC250250250250250250250250250250250

Continuous Current Rating(100% load factor) of Single Core XLPE Insulation Power Cable
Copper Conductor, CSA Sheath    Type: YJLW03(2)-Z

Rated Voltage




50/66 kV
Conductor Sectionmm2240300400500630800(C)800(M)100012001400160020002500
1)DirectlyBuriedTrefoilFormationA479539652734822906950104511101173122413141373
Flat FormationA52959772580993610501090122113131410148816411745
2) In AirTrefoilFormationA610692801916104411721239139215001610170318612010
Flat FormationA6777589021041120313711432163317781933206322972522
3) InDuctTrefoilFormationA5045696817498799831025114812341323139715201628
Flat FormationA5085746877678889921034115812461336141115361648
Max operating temp. of conductor.ºC90909090909090909090909090

Rated Voltage



64/110 kV
Conductor Sectionmm2240300400500630800(C)800(M)100012001400160020002500
1)DirectlyBuriedTrefoilFormationA527571647729766903946103511001165121812961368
Flat FormationA57262371481192210341076120212901384146315901709
2) In AirTrefoilFormationA605688793906103311631227137414801591168618411994
Flat FormationA6627588821017117313381403159417281878200622272449
3) InDuctTrefoilFormationA5225896737398689731014113112131300137214871592
Flat FormationA5255946797578769831023114212241312138515021610
Max operating temp. ofconductor.ºC90909090909090909090909090

Rated Voltage



127/220 kV
Conductor Sectionmm2400500630800(C)800(M)100012001400160020002500
1) DirectlyBuriedTrefoilFormationA635706799882919100910711134118612671342
Flat FormationA6867788829881028114912311317138915071613
2) In AirTrefoilFormationA772880100411301186133314361546164018011957
Flat FormationA840964111112641324150716351772189221032305
3) In DuctTrefoilFormationA649706831929966107711521229129413971487
Flat FormationA654727839938975108711631242130914151508
Max operating temp. ofconductor.ºC9090909090909090909090

Send your message to this supplier
Avatar
Mr. Percy Zhou
Export Sales
*From:
To: Mr. Percy Zhou
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category