Basic Info.
Application
Construction, Underground, Industrial, Power Station, Telecommunication, Computer
Voltage
High Voltage Cable
Cross Section
150-3000mm2
Conductor
Copper or Aluminum
Product Description
High Voltage XLPE Insulation PVC Sheath Electric Power Cable
1. Applicable Standard:
GB/T 11017-2014, GB/Z 18890, IEC 60840, IEC 62067
2. Advantages of XLPE insulated power cable
Compared with paper or PVC insulation cables, XLPE insulation power cables are with better electrical function performance, mechnical strength, aging-resistance, eco-friendly and corrosion resistance. Also, they are for more convenient installation and long time opertion in high temperature which can be laid without any drop restriction.
3. Product Description
Conductor | Adopting copper or aluminum, it depends on economic consideration. Tightly compressed conductor with good roundness and smooth surface. Those above 800mm2 adopt five sectors design to reduce skin effect and neighboring effect. Semi-conductive wrapping tape is to prevent penetration from inner screen to conductor and improve smoothness of inner screen. |
Inner/Outer screen | All adopt imported super-smooth cross-linked polyethylene screen material. The surface shall be smooth and electric field shall uniformly distribute. |
Insulation | Adopt imported super-smooth cross-linked polyethylene insulation material. Extruded with inner and outer screens together, compactly combined. Using gravity feeding to prevent external influences and ensure purity of raw material. Advanced process expels internal stress of insulation. High roundness and small eccentricity. |
Water buffer layer | High-performance water-blocking material ensures better water blocking property of cables. Buffer layer design ensures enough expansion space for insulation. |
Metallic screen | Meets the requirement of metallic screen and system short-circuit capacity. Radial waterproof corrugated aluminum sleeve has excellent mechanical strength to protect insulated cores of cable. Or, adopt copper wire screen. |
Bitumen | Anti-corrosion asphalt can effectively protect aluminum sleeve. |
Over sheath | Extruded PE or PVC material Optional low smoke low halogen and low smoke zero halogen material Optional flame retardant, termite prevention materials, to meet the need in different occasions. |
Semi-conductive layer | Continuous, bright graphite coating, as the electrode of outer sheath for voltage test. Optional extruded semi-conductive layer. |
4. Technical Data
Single Core, XLPE Insulation, Corrugated Aluminium Sheath, PE/PVC over sheath Power Cables
Copper Conductor, CSA Sheath Type: YJLW03(2)-Z
Rated Voltage | 50/66 kV |
Conductor | - nominal section | mm2 | 240 | 300 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
- shape | Compacted circular conductor | Milliken conductor |
- nominal diameter | mm | 18.4 | 20.6 | 23.8 | 26.6 | 30.0 | 33.8 | 35.1 | 39.3 | 42.2 | 45.7 | 48.7 | 54.5 | 60.9 |
Insulation | - nominal thickness | mm | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 | 14.0 |
- nominal diameter | mm | 49.0 | 51.2 | 54.4 | 57.2 | 60.6 | 64.4 | 67.1 | 71.9 | 74.8 | 78.3 | 81.3 | 87.1 | 93.5 |
CSA | - nominal thickness | mm | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.3 | 2.3 | 2.3 | 2.3 | 2.5 | 2.6 |
- nominal diameter | mm | 67.9 | 70.1 | 73.3 | 76.1 | 79.7 | 84.3 | 87.0 | 92.8 | 96.1 | 100.0 | 103.4 | 110.4 | 117.6 |
Non-metallic sheath - nominal thickness | mm | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 | 4.5 | 4.5 | 4.5 | 4.5 | 5.0 | 5.0 | 5.0 |
Cable - approx diameter | mm | 76.2 | 78.4 | 81.6 | 84.4 | 88.0 | 92.6 | 96.3 | 102.1 | 105.4 | 109.3 | 113.7 | 120.7 | 127.9 |
- approx weight | kg/m | 6.6 | 7.3 | 8.4 | 9.6 | 11.1 | 13.0 | 13.6 | 16.2 | 17.9 | 20.0 | 22.3 | 26.6 | 31.4 |
Mechanical, Electrical Performance |
Max pulling force | kN | 16.8 | 21.0 | 28.0 | 35.0 | 44.1 | 56.0 | 56.0 | 70.0 | 84.0 | 98.0 | 112.0 | 140.0 | 175.0 |
Min bending radius | mm | 1140 | 1180 | 1220 | 1270 | 1320 | 1390 | 1440 | 1530 | 1580 | 1640 | 1710 | 1810 | 1920 |
Conductor resistance - DC at 20ºC | Ω/km | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0221 | 0.0176 | 0.0151 | 0.0129 | 0.0113 | 0.0090 | 0.0072 |
- AC at 90ºC | Ω/km | 0.0970 | 0.0777 | 0.0613 | 0.0484 | 0.0383 | 0.0309 | 0.0287 | 0.0231 | 0.0200 | 0.0174 | 0.0154 | 0.0127 | 0.0107 |
Inductance - trefoil | mH/km | 0.473 | 0.456 | 0.435 | 0.420 | 0.404 | 0.390 | 0.391 | 0.380 | 0.372 | 0.363 | 0.358 | 0.348 | 0.337 |
- flat | mH/km | 0.757 | 0.734 | 0.705 | 0.683 | 0.659 | 0.635 | 0.628 | 0.605 | 0.591 | 0.575 | 0.562 | 0.540 | 0.517 |
Zero sequence impedance at 20ºC | Ω/km | 0.150+ j0.090 | 0.133+ j0.086 | 0.117+ j0.080 | 0.104+ j0.076 | 0.093+ j0.070 | 0.084+ j0.066 | 0.082+ j0.067 | 0.068+ j0.064 | 0.064+ j0.061 | 0.060+ j0.059 | 0.058+ j0.057 | 0.053+ j0.054 | 0.049+ j0.051 |
Core Capacitance | μF/km | 0.151 | 0.161 | 0.177 | 0.190 | 0.206 | 0.224 | 0.237 | 0.259 | 0.272 | 0.289 | 0.303 | 0.329 | 0.359 |
(50Hz)Charging current | A/km | 2.4 | 2.5 | 2.8 | 3.0 | 3.2 | 3.5 | 3.7 | 4.1 | 4.3 | 4.5 | 4.8 | 5.2 | 5.6 |
Short Circuit Rating |
Conductor, at 1s | kA | 34.9 | 43.5 | 57.9 | 72.3 | 91.0 | 115.4 | 115.4 | 144.1 | 172.8 | 201.4 | 230.1 | 287.4 | 359.1 |
Conductor, at 3s | kA | 20.4 | 25.4 | 33.7 | 42.1 | 52.9 | 67.1 | 67.1 | 83.7 | 100.3 | 116.9 | 133.5 | 166.7 | 208.1 |
Aluminium sheath, at 1s | kA | 41.1 | 42.5 | 44.6 | 46.5 | 48.8 | 51.5 | 53.3 | 64.8 | 67.1 | 69.9 | 72.3 | 76.8 | 81.7 |
Aluminium sheath, at 3s | kA | 24.8 | 25.6 | 26.9 | 28.0 | 29.4 | 31.1 | 32.2 | 38.9 | 40.3 | 41.9 | 43.4 | 45.9 | 48.8 |
Final Shart-circuit Temperature | ºC | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 |
Rated Voltage | 64/110 kV |
Conductor | - nominal section | mm2 | 240 | 300 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
- shape | Compacted circular conductor | Milliken conductor |
- nominal diameter | mm | 18.4 | 20.6 | 23.8 | 26.6 | 30.0 | 33.8 | 35.1 | 39.3 | 42.2 | 45.7 | 48.7 | 54.5 | 60.9 |
Insulation | - nominal thickness | mm | 19.0 | 18.5 | 17.5 | 17.0 | 16.5 | 16.0 | 16.0 | 16.0 | 16.0 | 16.0 | 16.0 | 16.0 | 16.0 |
- nominal diameter | mm | 59.0 | 60.2 | 61.4 | 63.2 | 65.6 | 68.4 | 71.1 | 75.9 | 78.8 | 82.3 | 85.3 | 91.1 | 97.5 |
CSA - nominal thickness | mm | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.0 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.5 | 2.6 |
- nominal diameter | mm | 80.3 | 81.5 | 82.5 | 84.7 | 87.5 | 90.7 | 93.4 | 99.2 | 102.7 | 106.6 | 110.2 | 117.4 | 124.0 |
Non-metallic sheath - nominal thickness | mm | 4.0 | 4.0 | 4.0 | 4.0 | 4.5 | 4.5 | 4.5 | 4.5 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 |
Cable - approx diameter | mm | 88.6 | 89.8 | 90.8 | 93.0 | 96.8 | 100.0 | 102.7 | 108.5 | 113.0 | 116.9 | 120.5 | 127.7 | 134.3 |
- approx weight | kg/m | 8.5 | 9.0 | 9.8 | 10.8 | 12.3 | 14.0 | 14.3 | 16.7 | 18.6 | 20.5 | 22.4 | 26.5 | 30.9 |
Mechanical, Electrical Performance |
Max pulling force | kN | 16.8 | 21.0 | 28.0 | 35.0 | 44.1 | 56.0 | 56.0 | 70.0 | 84.0 | 98.0 | 112.0 | 140.0 | 175.0 |
Min bending radius | mm | 1330 | 1350 | 1360 | 1400 | 1450 | 1500 | 1540 | 1630 | 1700 | 1750 | 1810 | 1920 | 2010 |
Conductor resistance - DC at 20ºC | Ω/km | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0221 | 0.0176 | 0.0151 | 0.0129 | 0.0113 | 0.0090 | 0.0072 |
- AC at 90ºC | Ω/km | 0.0970 | 0.0777 | 0.0613 | 0.0484 | 0.0383 | 0.0309 | 0.0287 | 0.0231 | 0.0200 | 0.0174 | 0.0154 | 0.0127 | 0.0107 |
Inductance - trefoil | mH/km | 0.503 | 0.483 | 0.458 | 0.439 | 0.423 | 0.406 | 0.403 | 0.392 | 0.386 | 0.377 | 0.370 | 0.359 | 0.347 |
- flat | mH/km | 0.757 | 0.734 | 0.707 | 0.683 | 0.659 | 0.635 | 0.628 | 0.605 | 0.591 | 0.575 | 0.562 | 0.540 | 0.517 |
Zero sequence impedance at 20ºC | Ω/km | 0.138+ j0.101 | 0.122+ j0.095 | 0.109+ j0.087 | 0.097+ j0.082 | 0.088+ j0.076 | 0.080+ j0.071 | 0.078+ j0.072 | 0.065+ j0.068 | 0.061+ j0.066 | 0.058+ j0.063 | 0.055+ j0.061 | 0.051+ j0.058 | 0.047+ j0.055 |
Core Capacitance | μF/km | 0.124 | 0.134 | 0.151 | 0.165 | 0.183 | 0.203 | 0.214 | 0.233 | 0.245 | 0.260 | 0.272 | 0.295 | 0.321 |
(50Hz)Charging current | A/km | 2.5 | 2.7 | 3.0 | 3.3 | 3.7 | 4.1 | 4.3 | 4.7 | 4.9 | 5.2 | 5.5 | 5.9 | 6.5 |
Short Circuit Rating |
Conductor, at 1s | kA | 34.9 | 43.5 | 57.9 | 72.3 | 91.0 | 115.4 | 115.4 | 144.1 | 172.8 | 201.4 | 230.1 | 287.4 | 359.1 |
Conductor, at 3s | kA | 20.4 | 25.4 | 33.7 | 42.1 | 52.9 | 67.1 | 67.1 | 83.7 | 100.3 | 116.9 | 133.5 | 166.7 | 208.1 |
Aluminium sheath, at 1s | kA | 48.9 | 49.7 | 50.5 | 51.8 | 53.4 | 55.5 | 57.2 | 69.2 | 71.6 | 74.4 | 76.9 | 81.4 | 86.1 |
Aluminium sheath, at 3s | kA | 29.5 | 30.0 | 30.5 | 31.2 | 32.2 | 33.5 | 34.5 | 41.5 | 43.0 | 44.7 | 46.1 | 48.7 | 51.5 |
Final short circuit Temperature | ºC | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 |
Rated Voltage | 127/220 kV |
Conductor | - nominal section | mm2 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
- shape | | Compacted circular conductor | Milliken conductor |
- nominal diameter | mm | 23.8 | 26.6 | 30.0 | 33.8 | 35.1 | 39.3 | 42.2 | 45.7 | 48.7 | 54.5 | 60.9 |
Insulation | - nominal thickness | mm | 27.0 | 27.0 | 26.0 | 25.0 | 24.0 | 24.0 | 24.0 | 24.0 | 24.0 | 24.0 | 24.0 |
- nominal diameter | mm | 81.4 | 84.2 | 85.6 | 87.4 | 89.7 | 91.9 | 94.8 | 98.3 | 101.3 | 107.1 | 113.5 |
CSA | - nominal thickness | mm | 2.4 | 2.4 | 2.4 | 2.4 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 | 2.8 | 2.8 |
- nominal diameter | mm | 108.5 | 119.0 | 113.5 | 115.9 | 118.4 | 121.0 | 124.3 | 128.2 | 131.2 | 137.4 | 143.8 |
Non-metallic sheath - nominal thickness | mm | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 | 5.0 |
Cable - approx diameter | mm | 118.8 | 129.3 | 123.8 | 126.2 | 128.7 | 131.3 | 134.6 | 138.5 | 141.5 | 147.7 | 154.1 |
- approx weight | kg/m | 14.4 | 15.5 | 16.8 | 18.5 | 18.7 | 20.9 | 22.6 | 24.6 | 26.5 | 30.8 | 35.2 |
Mechanical, Electrical Performance |
Max pulling force | kN | 28.0 | 35.0 | 44.1 | 56.0 | 56.0 | 70.0 | 84.0 | 98.0 | 112.0 | 140.0 | 175.0 |
Min bending radius | mm | 1780 | 1940 | 1860 | 1890 | 1930 | 1970 | 2020 | 2080 | 2120 | 2220 | 2310 |
Conductor resistance - DC at 20ºC | Ω/km | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0221 | 0.0176 | 0.0151 | 0.0129 | 0.0113 | 0.0090 | 0.0072 |
- AC at 90ºC | Ω/km | 0.0613 | 0.0484 | 0.0383 | 0.0309 | 0.0287 | 0.0231 | 0.0200 | 0.0174 | 0.0154 | 0.0127 | 0.0107 |
Inductance - trefoil | mH/km | 0.512 | 0.488 | 0.464 | 0.440 | 0.449 | 0.430 | 0.421 | 0.410 | 0.402 | 0.388 | 0.374 |
- flat | mH/km | 0.707 | 0.683 | 0.659 | 0.635 | 0.626 | 0.605 | 0.591 | 0.575 | 0.562 | 0.540 | 0.517 |
Zero sequence impedance at 20ºC | Ω/km | 0.094+ j0.105 | 0.083+ j0.100 | 0.074+ j0.093 | 0.068+ j0.087 | 0.067+ j0.087 | 0.057+ j0.081 | 0.054+ j0.078 | 0.051+ j0.075 | 0.049+ j0.072 | 0.045+ j0.068 | 0.042+ j0.065 |
Core Capacitance | μF/km | 0.117 | 0.125 | 0.137 | 0.151 | 0.157 | 0.173 | 0.181 | 0.191 | 0.199 | 0.215 | 0.232 |
(50Hz)Charging current | A/km | 4.7 | 5.0 | 5.5 | 6.1 | 6.3 | 6.9 | 7.2 | 7.6 | 7.9 | 8.6 | 9.3 |
Short Circuit Rating |
Conductor, at 1s | kA | 57.9 | 72.3 | 91.0 | 115.4 | 115.4 | 144.1 | 172.8 | 201.4 | 230.1 | 287.4 | 359.1 |
Conductor, at 3s | kA | 33.7 | 42.1 | 52.9 | 67.1 | 67.1 | 83.7 | 100.3 | 116.9 | 133.5 | 166.7 | 208.1 |
Aluminium sheath, at 1s | kA | 66.4 | 68.3 | 69.3 | 70.7 | 71.9 | 84.2 | 86.5 | 89.2 | 91.5 | 95.6 | 100.4 |
Aluminium sheath, at 3s | kA | 39.8 | 40.9 | 41.5 | 42.4 | 43.1 | 50.3 | 51.7 | 53.3 | 54.7 | 57.0 | 59.9 |
Final short circuit Temperature | ºC | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 | 250 |
5. Quality Assurance
Provide customers with fine products and service, fully follow ISO9001 qualify management system, from cable design, manufacturing, inspection, delivery to after sales service.
The 700kV 35A 24500kVA series resonance test system and type DDX-7000 partial discharge measuring instrument from Haefely in Switzerland can meet the requirement of cable factory routine test, sample test and some type test.
6. Cable Laying Condition
Rated Voltage | 50/66 kV |
Conductor Section | mm2 | 240 | 300 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
1) Directly Buried | Trefoil Formation | A | 479 | 539 | 652 | 734 | 822 | 906 | 950 | 1045 | 1110 | 1173 | 1224 | 1314 | 1373 |
Flat Formation | A | 529 | 597 | 725 | 809 | 936 | 1050 | 1090 | 1221 | 1313 | 1410 | 1488 | 1641 | 1745 |
2) In Air | Trefoil Formation | A | 610 | 692 | 801 | 916 | 1044 | 1172 | 1239 | 1392 | 1500 | 1610 | 1703 | 1861 | 2010 |
Flat Formation | A | 677 | 758 | 902 | 1041 | 1203 | 1371 | 1432 | 1633 | 1778 | 1933 | 2063 | 2297 | 2522 |
3) In Duct | Trefoil Formation | A | 504 | 569 | 681 | 749 | 879 | 983 | 1025 | 1148 | 1234 | 1323 | 1397 | 1520 | 1628 |
Flat Formation | A | 508 | 574 | 687 | 767 | 888 | 992 | 1034 | 1158 | 1246 | 1336 | 1411 | 1536 | 1648 |
Max operating temp. of conductor. | ºC | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Rated Voltage | 64/110 kV |
Conductor Section | mm2 | 240 | 300 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
1) Directly Buried | Trefoil Formation | A | 527 | 571 | 647 | 729 | 766 | 903 | 946 | 1035 | 1100 | 1165 | 1218 | 1296 | 1368 |
Flat Formation | A | 572 | 623 | 714 | 811 | 922 | 1034 | 1076 | 1202 | 1290 | 1384 | 1463 | 1590 | 1709 |
2) In Air | Trefoil Formation | A | 605 | 688 | 793 | 906 | 1033 | 1163 | 1227 | 1374 | 1480 | 1591 | 1686 | 1841 | 1994 |
Flat Formation | A | 662 | 758 | 882 | 1017 | 1173 | 1338 | 1403 | 1594 | 1728 | 1878 | 2006 | 2227 | 2449 |
3) In Duct | Trefoil Formation | A | 522 | 589 | 673 | 739 | 868 | 973 | 1014 | 1131 | 1213 | 1300 | 1372 | 1487 | 1592 |
Flat Formation | A | 525 | 594 | 679 | 757 | 876 | 983 | 1023 | 1142 | 1224 | 1312 | 1385 | 1502 | 1610 |
Max operating temp. of conductor. | ºC | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Rated Voltage | 127/220 kV |
Conductor Section | mm2 | 400 | 500 | 630 | 800(C) | 800(M) | 1000 | 1200 | 1400 | 1600 | 2000 | 2500 |
1) Directly Buried | Trefoil Formation | A | 635 | 706 | 799 | 882 | 919 | 1009 | 1071 | 1134 | 1186 | 1267 | 1342 |
Flat Formation | A | 686 | 778 | 882 | 988 | 1028 | 1149 | 1231 | 1317 | 1389 | 1507 | 1613 |
2) In Air | Trefoil Formation | A | 772 | 880 | 1004 | 1130 | 1186 | 1333 | 1436 | 1546 | 1640 | 1801 | 1957 |
Flat Formation | A | 840 | 964 | 1111 | 1264 | 1324 | 1507 | 1635 | 1772 | 1892 | 2103 | 2305 |
3) In Duct | Trefoil Formation | A | 649 | 706 | 831 | 929 | 966 | 1077 | 1152 | 1229 | 1294 | 1397 | 1487 |
Flat Formation | A | 654 | 727 | 839 | 938 | 975 | 1087 | 1163 | 1242 | 1309 | 1415 | 1508 |
Max operating temp. of conductor. | ºC | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Rating factor for ground temperature
Ambient temp.( ºC) | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 |
Effect coeff. | 1.07 | 1.04 | 1.00 | 0.96 | 0.93 | 0.89 | 0.84 | 0.80 |
Rating factor for soil thermal resistivity
Thermal coefficient (ºCm/W) | 0.7 | 1.0 | 1.2 | 1.5 | 2.0 | 2.5 | 3.0 |
Effect coeff. | 1.14 | 1.00 | 0.93 | 0.84 | 0.74 | 0.67 | 0.61 |
Rating factor for laying depth
Burial depth (M) | 0.50 | 0.70 | 0.90 | 1.00 | 1.20 | 1.50 |
Effect coeff. | 1.10 | 1.05 | 1.01 | 1.00 | 0.98 | 0.95 |
Rating factor for air temperature
Air Temp.( ºC) | 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 |
Effect coeff. | 1.28 | 1.24 | 1.19 | 1.15 | 1.10 | 1.05 | 1.00 | 0.95 | 0.89 | 0.83 | 0.77 |
Rating factor for phase spacing one group in flat formation
Laying space (mm) | D | D+70 | 250 | 300 | 350 | 400 |
Effect coeff. | D ≤ 80 | 0.93 | 1.00 | 1.05 | 1.07 | 1.08 | 1.09 |
81 < D ≤ 110 | 0.93 | 1.00 | 1.04 | 1.06 | 1.08 | 1.09 |
111 < D ≤ 140 | 0.93 | 1.00 | 1.03 | 1.06 | 1.09 | 1.11 |
Rating factor for groups of cables in the ground
Distance between groups(mm) | Number of groups |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
100 | 1.00 | 0.78 | 0.66 | 0.60 | 0.55 | 0.52 | 0.49 | 0.47 | 0.45 |
200 | 1.00 | 0.81 | 0.70 | 0.65 | 0.61 | 0.58 | 0.55 | 0.54 | 0.52 |
400 | 1.00 | 0.86 | 0.76 | 0.72 | 0.68 | 0.66 | 0.64 | 0.63 | 0.61 |
600 | 1.00 | 0.89 | 0.80 | 0.77 | 0.74 | 0.72 | 0.70 | 0.69 | 0.69 |
800 | 1.00 | 0.91 | 0.83 | 0.81 | 0.78 | 0.77 | 0.75 | 0.75 | 0.74 |
2000 | 1.00 | 0.96 | 0.93 | 0.92 | 0.91 | 0.91 | 0.90 | 0.90 | 0.90 |
7. Top Ranking Manufacture Equipment for HV/MV/LV of Power cables from Professional Suppliers
Name | Type | Origin | Application |
35KV Cable production line | CCV | Maillefer Finland | Production of medium voltage insulation wire core |
35KV Cable production line | CCV | TROESTER Germany | Production of medium voltage insulation wire core |
110KV Cable production line | CCV | TROESTER Germany | Production of high voltage insulation wire core |
500KV Cable production line | VCV | Maillefer Finland | Production of high voltage insulation wire core |
500KV Cable production line | VCV | TROESTER Germany | Production of high voltage insulation wire core |
35KV rubber cable production line | CCV | TROESTER Germany | Production of medium voltage rubber cables |
630 Frame type stranding machine | 91 wires | Pourtier France | Production for blocks of large section conductor |
3600 Drum-twister for milliken conductor | DPTC3600 | Pourtier France | Production for blocks of large section conductor |
High voltage cable out-sheath Product Line | Φ150+90 | Germany (Shanghai) TROESTER Machinery Co., Ltd. | Production for EHV cable double sheath |
Address:
12th Floor, Integrity Tower, No. 547 Museum Road, Hanjiang District, Yangzhou, Jiangsu, China
Business Type:
Manufacturer/Factory
Business Range:
Computer Products, Construction & Decoration, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001, HSE
Company Introduction:
Yangzhou Shuguang Cable Co., Ltd, was founded in 1985, a specialized wire and cable manufacturer lies in the northern suburb of famous and beautiful Yangzhou city with long history and culture.It is a "State-Grade Key High-Tech Enterprise", one of the "Top Hundred Chinese Electronic Information Enterprises", "Grade AAA Credit Enterprise", one of the enterprises who "Respects Contract and Keep Faith in Jiangsu province, "Excellent Provincial Private-Owned Enterprise", "Provincial Enterprise with Harmonious Labor Relations", and it obtained the first "Mayor Quality Award" in 2010.The series of "QIANG LING" branded cable products were awarded the "State Quality Inspection Exemption" and "Jiangsu Provincial Famous Brand".
With 92,000 square meters structure area in total 280,000 facility square meters, RMB 780 million Yuan self-owned net assets and nearly 800 workers and staffs, Shuguang took lead into passing ISO9001 Quality Management System in 1996, and successively passed Products Safety Certification, ISO14001 Environmental Management System, GB/T28001 Occupation Health & Safety Management System and ISO10012 Measurement Management System.We standardized our work process by adopting ERP Management System.
We provide more than 20 series of products including:Up to 500kV and 220kV cross-linking power cables, plastic cable, overhead insulated wire, shielded control and computer cable, irradiation cross-linking cable, Grade 1E Class K3 cable for nuclear power station, mine safety cable, rubber cable, wind energy cable, direct current cable, compensation cable, high temperature resistant cable, communication optical fiber cable, etc.Which are extensively applied in power, metallurgy, petro-chemical, energy, traffic, and telecommunication systems successively served in several domestic and overseas projects such as State Grid, Southern Power Grid, Three Gorge of Yangtze River, Datang Togtoh Power Station, Qinshan Nuclear Power Station, Sanmen Nuclear Power Station, CNPC Pengzhou 1 Million Tons/Years Ethylene Project, Changqing Oilfield, Changchun Rail Transporation, Zhongnanhai Substation, railway from Beijing to Tibet, Wuhan Iron and Steel Corp., SINOPEC Wuhan 800 Thousand Tons/Years Ethylene Project, BASF-YPC, Tongli ±800kV Converting Station, Southern Anhui 1000kV Substation, Sino-Burma Oil-Gas Pipeline Project, etc.The quality and services of our products received consistent praises from the clients and market.
With 8 Ult-high & High voltage cross-linking cable production lines, 2 conductor stranding production lines and full set of inspection equipment imported from Finland, Germany, America, UK, Swiss, Austria and other developed countries, Shuguang Cable drives ahead in the industry of wire and cable manufacture.After a long period of recruitment and education, we have formed up an excellent technical and management team which can promote the sustainable development of our company.We are vigorously strengthening the ability of research and development and innovation through enhancing the relationship and cooperation with colleges, universities and scientific and research institutions.We have successively assumed 79 provincial and above science and technology projects, including 8 National Important New Products projects, 13 National Torch Program and Spark Program projects, 3 national Innovation Fund projects and we also participated in drafting and revising of 24 national and industrial standards in cable industry.
"Striving cohesively, devoting selflessly, keeping progress with times and challenging the future" has been keeping as the enterprise culture to Shuguang people for years.During the sustainable development, Shuguang will further play full role of our advantages, by "Market Orientation, Customer Satisfaction, Innovation for development and Lean Management for benefit".Forge ahead and keep surpassing, we will always make contributions positively to harmonious society construction.